DTC P0192:
FRP Sensor Circuit Low Voltage
-
Turn the ignition switch ON (II).
-
Check the FRP SENSOR in the DATA LIST with the HDS.
|
Is about 0.25 V or less indicated?
|
|
YES
|
-
|
|
|
NO
|
-
|
Intermittent failure, the system is OK at this time. Check for poor connections or loose terminals at the FRP sensor and the ECM.■
|
-
Turn the ignition switch OFF, and wait 2 minutes.
-
Disconnect the FRP sensor 3P connector.
-
Turn the ignition switch ON (II).
-
Check the FRP SENSOR in the DATA LIST with the HDS.
|
Is about 0.25 V or less indicated?
|
-
Turn the ignition switch OFF, and wait 2 minutes.
-
Disconnect ECM connector No. 1 (96P).
-
Check for continuity between FRP sensor 3P connector terminal No. 2 and body ground.
|
YES
|
-
|
Repair short in the wire between the FRP sensor and ECM connector No. 1 terminal No. 40, then go to
Step 17
.
|
|
NO
|
-
|
|
|