Special Tools Required
NOTE: Refer to the Exploded View as needed during this procedure.
-
Clean all parts in solvent, dry them, and apply lubricant to all contact surfaces.
-
Install the distance collar and the needle bearing onto the countershaft.
-
Install the 1st gear synchro ring (A), synchro spring (B) and the friction damper (C) on the 1st/2nd synchro hub (D).
-
Align the fingers (E) on the friction damper with the grooves (F) on the 1st/2nd synchro hub, then install the 1st gear (G) onto the 1st/2nd synchro hub.
-
Supporting by hand, turn the 1st/2nd synchro hub side upward, then install the 1st/2nd synchro hub with 1st gear on to the counter shaft.
|