Hook up the following equipment:
-
Turn the ignition switch ON (II).
-
Select PGM-FI, INSPECTION, then ALL INJECTORS OFF on the HDS.
-
With the shift lever in N position, the brake pedal pressed, turn the ignition switch ON (II), and press the engine start switch.
|
Did the starter crank the engine normally?
|
|
YES
|
-
|
The starting system is OK. Go to
Step 21
.
|
|
NO
|
-
|
|
-
Check the battery condition.
Check electrical connections at the battery, the negative battery cable to body, the engine ground cables, and the starter for looseness and corrosion. Then try cranking the engine again.
|
Did the starter crank the engine?
|
|
YES
|
-
|
Repairing the loose connection corrected the problem. The starting system is OK. Go to
Step 23
.
|
|
NO
|
-
|
Check the following:
|
|
|