DTC A2-1x (‘‘x'' can be 0 thru 9 or A thru F):
Faulty Power Supply (VB Line)
-
Check the No. 11 (10 A) fuse in the under-dash fuse/relay box.
-
Replace the No. 11 (10 A) fuse.
-
Turn the ignition switch ON (II) and wait for 30 seconds. Then turn the ignition switch OFF.
-
Check the No. 11 (10 A) fuse.
|
YES
|
-
|
The system is OK at this time.■
|
|
NO
|
-
|
|
-
Replace the No. 11 (10 A) fuse.
-
Turn the ignition switch OFF. Disconnect the negative cable from the battery, and wait for 3 minutes.
-
-
Reconnect the negative cable to the battery.
-
Turn the ignition switch ON (II), and wait for 30 seconds. Then turn the ignition switch OFF.
-
Check the No. 11 (10 A) fuse.
|
YES
|
-
|
|
|
NO
|
-
|
Short to ground in the dashboard wire harness or in the under-dash fuse/relay box No. 11 (10 A) fuse line; replace the dashboard wire harness. If the problem is still there,
replace the under-dash fuse/relay box.
■
|
-
Turn the ignition switch OFF. Disconnect the negative cable from the battery, and wait for 3 minutes.
-
-
Reconnect the negative cable to the battery.
-
Connect a voltmeter between the No. 18 terminal of SRS unit connector A (28P) and body ground. Turn the ignition switch ON (II), and measure voltage. There should be battery voltage when the ignition on.
|
Is there battery voltage?
|
|
YES
|
-
|
Faulty SRS unit or poor connection at SRS unit connector A (28P) and the SRS unit; check the connection. If the connection is OK,
replace the SRS unit.
■
|
|
NO
|
-
|
|
-
Turn the ignition switch OFF.
|