Door Lock Actuator Test

Driver's Door Lock Actuator
  1. Disconnect the 10P connector (A) from the door lock actuator.

  1. Check actuator operation by connecting power and ground according to the table. To prevent damage to the actuator, apply battery voltage only momentarily.
  1. If the actuator does not work as specified, replace it.

Driver's Super Locking Actuator
  1. Disconnect the 10P connector (A) from the door lock actuator.
  1. Connect power to the No. 1 terminal and ground to the No. 2 terminals momentarily. The actuator should operate.
  1. If the actuator does not operate as specified, replace it.

Passenger's Door Lock Actuator
  1. Disconnect the 10P connector (A) from the door lock actuator.

  1. Check actuator operation by connecting power and ground according to the table. To prevent damage to the actuator, apply battery voltage only momentarily.
  1. If the actuator does not work as specified, replace it.

Passenger's Super Locking Actuator
  1. Disconnect the 10P connector (A) from the door lock actuator.
  1. Connect power to the No. 3 terminal and ground to the No. 4 terminals momentarily. The actuator should work.
  1. If the actuator does not work as specified, replace it.